EKOHEAT induction heating systems include the EKOHEAT power supply and workhead to which the work coil is attached. The EKOHEAT system operates in parallel resonance. So the EKOHEAT workheads are all configured for parallel resonance and built with capacitors specifically selected to operate over the operating band of the power supply and capable of delivering the rated power to the part being heated.

 

Contact Us  Get a Quote

Ambrell EKOHEAT 100kHz workheads (outlines D and E)
Max Power (kW) Dimensions Configuration Image
10, 15, 30, 45 H: 152 (6) | W: 152 (6) | D: 305 (12) | CH: 102 (4) | CW: 76 (3) 1600 kVAR; (4) CPRI400 D
45, 65, 90, 135, 180, 225, 270 H: 229 (9) | W: 203 (8) | D: 457 (18) | CH: 111 (4.39) | CW: 97 (3.81) 3200 kVAR; (8) CPRI400 E
Ambrell EKOHEAT 25kHz workheads (outlines F, G, H, I, J and K)
Max Power (kW) Dimensions Configuration Image
20, 35, 50, 75, 100, 150 H: 194 (7.64) | W: 314 (12.4) | D: 508 (20) | CH: 81 (3.2) | CW: 157 (6.19) 2000 kVAR; (4) C500T F
75, 100, 150, 200, 300, 400 H: 358 (14.1) | W: 354 (13.9) | D: 609 (24) | CH: 172 (6.8) | CW: 177 (6.9) 4000kVAR; (8) C500T G
75, 100, 150, 200, 300,400 H: 648 (25.5) | W: 334 (13.2) | D: 906 (35.7) | CH: 422 (16.61) | CW: 152 (6) 1800kVAR; 10uF@1000V | 2400kVAR; 5uF@1600V | 2130kVAR; 53.6uF@800V H
75, 100, 150, 200, 300, 400 H: 711 (28) | W: 914 (36) | D: 930 (36.6) | CH: 480 (18.9) | CW: 419 (16.5) 3600 kVAR; 20uF@1000V | 4800 kVAR; 10uF@1600V | 4260kVAR | 107.2uF@800V | 4260 kVAR 26.8uF@1600V I
150, 200, 300, 400, 500 H: 711 (28) | W: 914 (36) | D: 1387 (54.6) | CH: 480 (18.9) | CW: 457 (18) 5400kVAR; 30uF@1000V | 7200kVAR; 15uF@1600V | 6390kVAR 160.8uF@800V J
300, 400, 500 H: 358 (14.1) | W: 354 (13.9) | D: 609 (24) | CH: 172 (6.8) | CW: 177 (6.9) 10800kVAR 60uF@1000V | 14400kVAR 30uF@1600V | 12780kVAR 321.6uF@800V | 12780kVAR 80.4uF@1600V K
Ambrell EKOHEAT 10kHz workheads (outlines F, G, H, I, J and K)
Max Power Dimensions Configuration Image
25, 35, 50, 75,100, 125, 200, 250,300, 375, 500 H: 194 (7.64) | W: 314 (12.4) | D: 508 (20) | CH: 81 (3.2) | CW: 157 (6.19) 2000 kVAR; (4) C500T F
75, 100, 125, 200, 250,300, 375, 500 H: 358 (14.1) | W: 354 (13.9) | D: 609 (24) | CH: 172 (6.8) | CW: 177 (6.9) 4000kVAR; (8) C500T G
75, 100, 125, 200, 250, 300, 375, 500 H: 648 (25.5) | W: 334 (13.2) | D: 906 (35.7) | CH: 422 (16.61) | CW: 152 (6) 1800kVAR; 10uF@1000V | 2400kVAR; 5uF@1600V | 2130kVAR; 53.6uF@800V H
75, 100, 125, 200, 250, 300, 375, 500 H: 711 (28) | W: 914 (36) | D: 930 (36.6) | CH: 480 (18.9) | CW: 419 (16.5) 3600 kVAR; 20uF@1000V | 4800 kVAR; 10uF@1600V | 4260kVAR | 107.2uF@800V | 4260 kVAR 26.8uF@1600V I
125, 200, 250, 300, 375, 500 H: 711 (28) | W: 914 (36) | D: 1387 (54.6) | CH: 480 (18.9) | CW: 457 (18) 5400kVAR; 30uF@1000V | 7200kVAR; 15uF@1600V | 6390kVAR 160.8uF@800V J
300, 375, 500 H: 358 (14.1) | W: 354 (13.9) | D: 609 (24) | CH: 172 (6.8) | CW: 177 (6.9) 10800kVAR 60uF@1000V | 14400kVAR 30uF@1600V | 12780kVAR 321.6uF@800V | 12780kVAR 80.4uF@1600V K
Ambrell EKOHEAT 3kHz workheads (outlines F, G, H, I, J and K)
Max Power Dimensions Configuration Image
75, 100, 125, 150, 200, 250, 300, 375, 500 H: 648 (25.5) | W: 334 (13.2) | D: 906 (35.7) | CH: 422 (16.61) | CW: 152 (6) 1800 kVAR; 10uF@1000V | 2400 kVAR; 5uF@1600V | 2130 kVAR; 53.6uF@800V H
75, 100, 125, 150, 200, 250, 300, 375, 500 H: 711 (28) | W: 914 (36) | D: 930 (36.6) | CH: 480 (18.9) | CW: 419 (16.5) 3600 kVAR; 20uF@1000V | 4800 kVAR; 10uF@1600V | 4260 kVAR; 107.2uF@800V | 4260 kVAR; 26.8uF@1600V I
150, 200, 250, 300, 375, 500 H: 711 (28) | W: 914 (36) | D: 1387 (54.6) | CH: 480 (18.9) | CW: 457 (18) 5400kVAR; 30uF@1000V | 7200kVAR; 15uF@1600V | 6390kVAR 160.8uF@800V J
300, 375, 500 H: 711 (28) | W: 914 (36) | D: 1844 (72.6) | CH: 607 (23.9) | CW: 457 (18) 10800kVAR 60uF@1000V | 14400kVAR 30uF@1600V | 12780kVAR 321.6uF@800V | 12780kVAR 80.4uF@1600V K