EKOHEAT® 10 & 15 kW SYSTEMS

meter-bolt-regular-full

Max Power
10 & 15 kW

waves-sine-regular-full

Frequency
50 - 150 kHz

bolt-regular-full

Line Voltage
360 - 520, 3Ø Vac

EKOHEAT_Compact

Induction Heating Systems

Our reliable and repeatable solutions for:

  • heating smaller parts

  • high-frequency heating

  • heat treating steel

  • shallow case depth hardening

  • brazing, shrink fitting, curing, forming and melting

EKOHEAT 15/100 Group is Versatile

  • Efficient heating of many part geometries, sizes and compositions

  • Configurable voltage, power and transformer tapping

  • Through-Curie heating

  • Sub-second to continuous cycle times

  • Remote operation or logging with RS485 port

EKOHEAT 15/100 Group is Easy to Use

  • User-friendly operator front panel controls

  • System configuration from front panel

  • Cycle timer, peak and short-cycle data capture

  • 10 ten-step heating profiles

  • 5-language display suite (EN, ES, FR, DE, IT)

  • CE marked; IS0 9001:2015

  • rapid tuning

  • efficient, precise heating 

  • power control within 0.2% resolution

Download the Data Sheet: EN | EN | FR | IT | DE | ES

Select an option below:
  • 10 kW
  • 15 kW

SPECIFICATION

VALUE

UNITS

RF Terminal Power1

9

kW

AC Line Power

10

kVA

AC Line Protection2

35

A

Output Frequency

50 - 150

kHz

Power Factor

0.92

 

AC Line Voltage

360 - 520

Vac

Display

LCD Monochrome, 240w x 128h Pixels

 

Serial Communications

RS485 standard (RS485/232 converter optional)

Optional

Process Timer

0.01 - 10000

sec

Max Ambient Temp

45 (115)

C° (F°)

Compliance3

CE, UKCA, EN60519, EN61326-1

 

Ingress Protection

NEMA12

 

Dimensions

432 x 616 x 451 (17 x 24.25 x 17.75)

WxDxH mm (in)

Weight

32 (70)

kg (lb)

WATER COOLING

Flow4

7.6 (2.0) + 2.8 (0.75)

l/m (g/m)

Max Input Pressure

5.6 (80)

bar (lb/in2)

Pressure Differential

2.8 - 5.6 (40-80)

bar (lb/in2)

Max Water Temp

35 (95)

C° (F°)

1) Maximum output may vary based on frequency and load conditions
2) fast-acting fuses
3) Suitable for incorporation into equipment for compliance with Machinery Directive
4) Power supply + workhead caps; required workhead coil flow requirements vary by application

SPECIFICATION

VALUE

UNITS

RF Terminal Power1

14

kW

AC Line Power

15

kVA

AC Line Protection2

35

A

Output Frequency

50 - 150

kHz

Power Factor

0.92

 

AC Line Voltage

360 - 520

Vac

Display

LCD Monochrome, 240w x 128h Pixels

 

Serial Communications

RS485 standard (RS485/232 converter optional)

Optional

Process Timer

0.01 - 10000

sec

Max Ambient Temp

45 (115)

C° (F°)

Compliance3

CE, UKCA, EN60519, EN61326-1

 

Ingress Protection

NEMA12  

Dimensions

432 x 616 x 451 (17 x 24.25 x 17.75)

WxDxH mm (in)

Weight

32 (70)

kg (lb)

WATER COOLING

Flow4

7.6 (2.0) + 2.8 (0.75)

l/m (g/m)

Max Input Pressure

5.6 (80)

bar (lb/in2)

Pressure Differential

2.8 - 5.6 (40-80)

bar (lb/in2)

Max Water Temp

35 (95)

C° (F°)

1) Maximum output may vary based on frequency and load conditions
2) fast-acting fuses
3) Suitable for incorporation into equipment for compliance with Machinery Directive
4) Power supply + workhead caps; required workhead coil flow requirements vary by application

Four Ways To Contact Ambrell for Support

AMBRELL CORPORATION

1655 Lyell Avenue
Rochester, NY 14606
United States

 Directions to Ambrell Corporation Directions
T: +1 585 889 9000
F: +1 585 889 4030
Contact Sales
Contact Orders
Contact Service

AMBRELL B.V.

Holtersweg 1
7556 BS Hengelo
The Netherlands

Directions to Ambrell B. V. Directions
T: +31 880 150 100
F: +31 546 788 154
Contact Sales
Contact Orders
Contact Service

AMBRELL Ltd.

Front Suite, 1st Floor, Charles House
148-149 Gt Charles Street
Birmingham, B3 3HT
United Kingdom

T: +44 1242 514042
F: +31 546 788 154
Contact Sales
Contact Orders
Contact Service